MAIN PAGE > PRODUCTS > HT-504 > MATERIAL SAFETY DATA SHEET | BACK ONE |
SECTION I Identification Manufacturer: Hydrochemical Techniques Inc P.O.Box 2078 Hartford, Connecticut 06145 Product Name: Hydroclean HT-504 Grease & Oil Emulsifier Emergency Telephone Number: (800) 278-7681 Date Prepared: August 29, 2007 |
SECTION II Hazardous Ingredients Chemical Name: Petroleum Naphtha - CAS Number 64742-95-6, 100 TLV (UNITS) *A TLV has not been established for this product. The value shown has been established by Shell Oil Company based on consideration of available toxicological data. Additional data is being obtained to help define a recommended occupational exposure limit more conclusively. |
SECTION III Physical Data Boiling Point (°F): 320-350° Vapor Pressure (mm Hg): 4.8 @ 100 degrees F Vapor Density (Air = 1): 4.3 Solubility In Water (20°C): 100% Appearance & Odor: Mild Aromatic Odor Specific Gravity: .88 Percent, Volatile/Volume: 100 Evaporation Rate: Not Available pH: Not Applicable |
SECTION IV Fire & Explosion Hazard Data Flash Point (Method Used): 150°F TCC COMBUSTIBLE UN 1268 Flammable Limits: Not Applicable Extinguishing Media: Foam, dry chemical, CO2, water fog or spray. Special Fire Fighting Procedures: Wear NIOSH/MSHA approved self-contained breathing apparatus. Wear a full face piece operated in pressure demand or other positive pressure mode when fighting fires. |
SECTION V Health Hazard Data Threshold Limit Value: 100 TLV *(See above) Effects of Overexposure: Inhalation of high vapor concentrations may have results ranging from dizziness and headaches to unconsciousness. May dry out skin leading to irritation and dermatitis. Emergency & First Aid Procedures: Eyes - Flush with water. Skin - Wash area with soap and water. Ingestion - Do Not Induce Vomiting - call a physician. If overcome by vapor, remove from exposure and immediately call a physician. |
SECTION VI Reactivity Data Stability: Stable Incompatability (Materials to Avoid): Do not store or mix with strong oxidants like liquid chlorine or concentrated oxygen. Hazardous Decomposition Products: Fumes, smoke and carbon monoxide in the case of incomplete combustion. Conditions to Avoid: None |
SECTION VII Spill, Leak or Waste Disposal Procedures Spills or Leaks: Remove all ignition sources. Recover free liquid. Add absorbent (sand, earth, etc.) to spill area. Avoid breathing vapors. Ventilate area. Keep out of sewers and watercourses by diking or impounding. Waste Disposal: Dispose in a manner approved by State, Federal and Local laws. |
SECTION VIII Special Protection Respiratory: Use hydrocarbon vapor canister or supplied air respiratory protection in confined areas. Ventilation: Use only with adequate ventilation. Gloves: Use chemical resistant gloves. Eye: Use goggles or protective face shield. OTHER PROTECTIVE: Use chemical resistant apron or other clothing to avoid prolonged skin contact. |
SECTION IX Special Precautions Handling & Storage: Keep containers closed when not in use. Do not store near heat, sparks, flame or oxidants. Other Precautions: COMBUSTIBLE. No smoking near HT-504 vapors. |
MAIN PAGE > PRODUCTS > HT-504 > MATERIAL SAFETY DATA SHEET : TOP |
http://www.hydroclean.com All information and photos are copyright Hydroclean. No material may be reproduced without express written permission from Hydrochemcial Techniques, Inc. HYDROCLEAN Hydrochemical Techniques, Inc. PO Box 2078 Hartford, CT 06145 Tel: 800-278-7681 860-527-6350 Fax: 860-527-4067 info@hydroclean.com |